Effect of strength of filled-concrete on structural performance of continuous beam-type square CFST beam-to-column connection
著者
著者名
Doi, Koki
著者ID
A0927
研究者ID
1000010304130
KUID
https://kuid-rm-web.ofc.kobe-u.ac.jp/search/detail?systemId=14d4342f1a02a66d520e17560c007669
著者名
Fujinaga, Takashi
藤永, 隆
フジナガ, タカシ
所属機関名
都市安全研究センター
言語
English (英語)
収録物名
Proceedings of International Structural Engineering and Construction
巻(号)
8(1)
ページ
STR-27-1-STR-27-6
出版者
ISEC Press
刊行日
2021-07
公開日
2022-10-07
抄録
Continuous beam-type concrete-filled steel tube (CFST) column connections are simple to fabricate and exhibit effective seismic performance. Fujinaga and Clifton have previously studied the performance of continuous beam-type square CFST beam-to-column connections using concrete of relatively high strength (85 MPa) and demonstrated their effective performance and high energy-absorbing capacity. However, in their study, it was found that the local deformation of the steel beam under bending-induced beam tension had a large effect on the steel tube flange near the connection. Further, it was observed that filled concrete may not contribute substantially to the transmission of compressive load at the connection panel if low-strength concrete is used. In this study, the square CFST beam-to-column connection was investigated, and the connection performance and load transfer mechanisms were examined when the strength of the concrete was relatively low (40 MPa). The specimens demonstrated effective seismic performance, exhibiting sufficient strength and stable hysteretic behavior with high energy absorption even when low-strength concrete was used. Irrespective of the strength of the concrete used, the strain developed in the steel tube flanges was low on the compression side, and the filled concrete contributed to the transmission of the compressive load at the connection panel. The compressive strain in the steel tube was slightly higher when the strength of the concrete was low.
キーワード
Concrete-filled steel tube
Cruciform shape
T-shape
Fillet welding
Energy absorption
Strain distribution
カテゴリ
都市安全研究センター
学術雑誌論文
権利
© 2021 ISEC Press
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
関連情報
DOI
https://doi.org/10.14455/ISEC.2021.8(1).STR-27
詳細を表示
資源タイプ
journal article
eISSN
2644-108X
OPACで所蔵を検索
CiNiiで学外所蔵を検索
ホームへ戻る