神戸大学附属図書館デジタルアーカイブ
入力補助
English
カテゴリ
学内刊行物
ランキング
アクセスランキング
ダウンロードランキング
https://hdl.handle.net/20.500.14094/0100483397
このアイテムのアクセス数:
118
件
(
2025-09-08
04:43 集計
)
閲覧可能ファイル
ファイル
フォーマット
サイズ
閲覧回数
説明
0100483397 (fulltext)
pdf
975 KB
75
メタデータ
ファイル出力
メタデータID
0100483397
アクセス権
open access
出版タイプ
Version of Record
タイトル
Structural properties in ruptured mitral chordae tendineae measured by synchrotron-based X-ray phase computed tomography
著者
Koda, Yojiro ; Tsukube, Takuro ; Hoshino, Masato ; Yagi, Naoto ; Ishibashi-Ueda, Hatsue ; Okada, Kenji
著者ID
A3014
KUID
https://kuid-rm-web.ofc.kobe-u.ac.jp/search/detail?systemId=491b1635c468ee15520e17560c007669
著者名
Koda, Yojiro
幸田, 陽次郎
コウダ, ヨウジロウ
所属機関名
医学部附属病院
著者名
Tsukube, Takuro
著者名
Hoshino, Masato
著者名
Yagi, Naoto
著者名
Ishibashi-Ueda, Hatsue
著者ID
A2433
研究者ID
1000090284356
KUID
https://kuid-rm-web.ofc.kobe-u.ac.jp/search/detail?systemId=de64348f5726e507520e17560c007669
著者名
Okada, Kenji
岡田, 健次
オカダ, ケンジ
所属機関名
医学研究科
言語
English (英語)
収録物名
Journal of Synchrotron Radiation
巻(号)
30(5)
ページ
995-1002
出版者
International Union of Crystallography
刊行日
2023-09-01
公開日
2023-10-24
抄録
The link between the structural properties and the rupturing of chordae tendineae in the mitral valve complex is still unclear. Synchrotron-radiation-based X-ray phase computed tomography (SR-XPCT) imaging is an innovative way to quantitatively analyze three-dimensional morphology. XPCT has been employed in this study to evaluate the chordae tendineae from patients with mitral regurgitation and to analyze structural changes in the ruptured chordae tendineae in patients with this condition. Six ruptured mitral chordae tendineae were obtained during surgical repairs for mitral regurgitation and were fixed with formalin. In addition, 12 healthy chordae tendineae were obtained from autopsies. Employing XPCT (effective pixel size, 3.5 µm; density resolution, 1 mg cm⁻³), the density of the chordae tendineae in each sample was measured. The specimens were subsequently analyzed pathologically. The mean age was 70.2 ± 3.0 in the rupture group and 67.2 ±14.1 years old in the control group (p = 0.4927). All scans of chorda tendineae with SR-XPCT were performed successfully. The mean densities were 1.029 ±0.004 in the rupture group and 1.085 ± 0.015 g cm⁻³ in the control group (p < 0.0001). Density based on SR-XPCT in the ruptured mitral chordae tendineae was significantly lower compared with the healthy chorda tendinea. Histological examination revealed a change in the components of the connective tissues in ruptured chorda tendinea, in accordance with the low density measured by SR-XPCT. SR-XPCT made it possible to measure tissue density in mitral chordae tendineae. Low density in mitral chordae tendineae is associated with a greater fragility in ruptured mitral chordae tendineae.
キーワード
synchrotron-based X-ray phase computed tomography
mitral valve
mitral chorda
mitral chorda rupture
mitral valve structure
カテゴリ
医学研究科
医学部附属病院
学術雑誌論文
権利
© 2023 Yojiro Koda et al.
This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.
関連情報
DOI
https://doi.org/10.1107/S1600577523005167
詳細を表示
資源タイプ
journal article
eISSN
1600-5775
OPACで所蔵を検索
CiNiiで学外所蔵を検索
ホームへ戻る