神戸大学附属図書館デジタルアーカイブ
論文登録申請
入力補助
English
カテゴリ
学内刊行物
ランキング
アクセスランキング
ダウンロードランキング
https://doi.org/10.24546/81012993
このアイテムのアクセス数:
69
件
(
2026-08-11
08:45 集計
)
閲覧可能ファイル
ファイル
フォーマット
サイズ
閲覧回数
説明
81012993 (fulltext)
pdf
330 KB
29
メタデータ
ファイル出力
メタデータID
81012993
アクセス権
open access
出版タイプ
Version of Record
タイトル
HbA1c levels Measured by Enzymatic Assay and Immunoassay during Off-Site Health Checkups Are Both Lower than Those Measured by On-Site HPLC Assay
著者
Goya, Kayoko ; Tanaka, Sayaka ; Toki, Makio ; Kanno, Mayu ; Tabuchi, Yukiko ; Fukuzawa, Keisuke ; Nonoguchi, Kazuhiro ; Ishibash, Midori ; Koga, Masafumi
著者名
Goya, Kayoko
著者名
Tanaka, Sayaka
著者名
Toki, Makio
著者名
Kanno, Mayu
著者名
Tabuchi, Yukiko
著者名
Fukuzawa, Keisuke
著者名
Nonoguchi, Kazuhiro
著者名
Ishibash, Midori
著者名
Koga, Masafumi
言語
English (英語)
収録物名
The Kobe journal of the medical sciences
巻(号)
66(5)
ページ
170-174
出版者
神戸大学医学部
Kobe University School of Medicine
刊行日
2020
公開日
2021-11-15
抄録
It has already been reported that HbA1c levels measured by immunoassay (IA) (IA-HbA1c) during off-site health checkups present falsely lower results. We also reported that HbA1c levels measured by enzymatic assay (EA) (EA-HbA1c) during off-site health checkups are lower. In the present study, we compared IA-HbA1c levels or EA-HbA1c levels during off-site health checkups with on-site high-performance liquid chromatography (HPLC)-HbA1c levels using the same samples. Subjects were 88 non-diabetic individuals who had health checkups in Nishinomiya Municipal Central Hospital. Subjects with a history of diabetes mellitus and those with HPLC-HbA1c ≥ 6.5% were excluded. IA-HbA1c levels (Study 1) or EA-HbA1c levels (Study 2) in the health checkups were compared with on-site HPLC-HbA1c levels using the same samples. Both IA-HbA1c levels and EA-HbA1c levels had positive correlations with HPLC-HbA1c levels (p <0.0001 for both), although both were significantly lower than HPLC-HbA1c levels (p <0.0001 for both). The degrees of reductions in the IA-HbA1c levels and EA-HbA1c levels compared with HPLC-HbA1c levels were almost same to each other. Similarly to IA-HbA1c levels, EA-HbA1c levels during the health checkups were lower than HPLC-HbA1c levels. It was demonstrated that HbA1c levels decrease similarly if measured by either EA or IA during off-site health checkups.
キーワード
HbA1c
Immunoassay
Enzymatic assay
HPLC
Health checkup
カテゴリ
The Kobe journal of the medical sciences
>
66巻
>
66巻5号(2020)
紀要論文
関連情報
URI
https://www.med.kobe-u.ac.jp/journal/contents.html
詳細を表示
資源タイプ
departmental bulletin paper
ISSN
0023-2513
OPACで所蔵を検索
CiNiiで学外所蔵を検索
NCID
AA00711740
OPACで所蔵を検索
CiNiiで表示
ホームへ戻る